Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Year range
1.
Article | IMSEAR | ID: sea-223557

ABSTRACT

Background & objectives: The diagnosis of scrub typhus (ST) is usually done using enzyme-linked immunosorbent assay (ELISA) due to its ease of performance and reading objectivity. The cut-off value for ELISA needs to be calculated for each geographical location as it depends on zonal endemicity of the disease. This study was, therefore, undertaken to calculate the pan-India cut-off for anti-Orientia tsutsugamushi (OT) immunoglobulin M (IgM) by ELISA. Methods: Samples from cases (cases of ST) and controls (voluntary, consenting, healthy adults) were collected by a network of 29 laboratories across India and tested for anti-OT IgM by immunofluorescence assay (IFA), the considered gold standard test. These samples were retested by ELISA for anti-OT IgM and their optical densities (ODs) were used for cut-off estimation by receiver operating characteristic (ROC) curve. Results: Anti-OT IgM ELISA ODs from 273 controls and 136 cases were used for the cut-off estimation. The ODs of the anti-OT IgM ELISA on healthy individuals and those of confirmed ST cases ranged from 0.1 to 0.75 and 0.5 to 4.718, respectively. ROC curve-based cut-off for ELISA was calculated as 0.554 at a sensitivity of 95.2 per cent and specificity of 95.1 per cent. A value of >1 was noted to have a specificity of 100 per cent in diagnosing ST. Interpretation & conclusions: The cut-off calculated for India was similar to the previous cut-off that was used until now.

2.
Article | IMSEAR | ID: sea-223633

ABSTRACT

To implement the strategy of test, track and treat to tackle the ongoing COVID-19 pandemic, the number of real-time RT-PCR–based testing laboratories was increased for diagnosis of SARS-CoV-2 in the country. To ensure reliability of the laboratory results, the Indian Council of Medical Research initiated external quality assessment (EQA) by deploying inter-laboratory quality control (ILQC) activity for these laboratories by nominating 34 quality control (QC) laboratories. This report presents the results of this activity for a period of September 2020 till November 2020. A total of 597 laboratories participated in this activity and 86 per cent of these scored ?90 per cent concordance with QC laboratories. This ILQC activity showcased India’s preparedness in quality diagnosis of SARS-CoV-2.

SELECTION OF CITATIONS
SEARCH DETAIL